ConformX
Visco-elastic foam mattress range
A layer of visco-elastic foam provides support to the patient for pressure redistribution. The ConformX range was specifically developed with patient comfort and pressure injury management in mind, and provides a 24 hour solution.
Safe and convenient for patients and carers
Designed to provide effective pressure redistribution.
The ConformX mattress replacement is available in multiple sizes and has been tested for X-Ray translucency¹ and is suitable for CPR². In addition, the overlay includes corner securing straps for extra security.
References:
1. Arjo Data on File: ConformX X-ray Attenuation. Report Number 100076011, April 2002.
2. Arjo Data on File Cardiopulmonary Resuscitation (CPR) for Foam Mattresses. Report Number 100076011, 2005.
• Ultra two way stretch
• Vapour permeable
• Water resistant
• Infection Control is aided by Antimicrobial properties in the cover material
• Non slip silver base
• Easy to clean and maintain
• Concealed zip
• Clearly marked covers with TurnTable® guide and washing instructions
Memory foam
• Gently moulds to patient’s body
Concealed zip
• The cover has a concealed zip designed to help improve infection prevention protocols
Suitable for profiling beds
• Suitable for us in the gatched or supine position
Silver base material
• Offering non slip properties
Dimensions | |
---|---|
Mattress A Name | MR Acute |
Mattress A (L x W x H) mm | 1980 x 860 x 150 mm |
Mattress A (L x W x H) in | 78 x 33.75 x 6 in |
Mattress B Name | MR Standard |
Mattress B (L x W x H) mm | 1900 x 920 x 150 mm |
Mattress B (L x W x H) in | 74.75 x 36.25 x 6 in |
Mattress C Name | MR Double |
Mattress C (L x W x H) mm | 1900 x 1380 x 150 mm |
Mattress C (L x W x H) in | 74.75 x 54.25 x 6 in |
Mattress D Name | MR Euro Wide |
Mattress D (L x W x H) mm | 2040 x 920 x 150 mm |
Mattress D (L x W x H) in | 80.25 x 36.25 x 6 in |
Mattress E Name | MR Euro Narrow |
Mattress E (L x W x H) mm | 2000 x 800 x 150 mm |
Mattress E (L x W x H) in | 78.75 x 31.5 x 6 in |
Maximum patient weight kg | 150 kg |
Maximum patient weight lb | 330 lb |
x-ray | Tested to FDA 21 CFR Ch. 1 (4-1-95 Edition) HHS & CEI/IEC 601-1-3: 1994-07 (X-ray attenuation). |
CPR | Chest Compression for CPR purposes is not impeded |
Pump | |
Standards | MR System meets BS EN 597 -1: 1995 BS EN 597 -2: 1995 and BS 6807: 1996, Section 2, Ignition Sources 0,1 and 5. Overlay System meets BS EN 597-1: 1995, BS EN 597 -2: 1995 and BS 6807: 1996, Section 2, Ignition Sources 0,1 and 5 |
ConformX Instructions for use 2 Way Turn Mattress Overlay
ConformX - 2-Way Turn Mattress Overlay - Instructions for Use
Category: Instructions for use
File name: 408902_INT1_02.pdf
Type: PDF
Size: 0.69 Mb
[ML(EN, ZH) for CN, INT, US, AU, GB] [ML(DA, DE, EN, ES, FR, HR, IT, NL, SL, SR, SV) for HR, DK, FR, DE, INT, IT, NL, RS, SI, ES, SE, US, AU, GB, CH, AT]
ConformX Instructions for use 2 Way Turn Mattress Replacement
Category: Instructions for use
File name: 408901_INT1_03.pdf
Type: PDF
Size: 0.91 Mb
EN-US [ML(EN, ZH) for CN, INT, US, AU, GB] [ML(BG, CS, DA, DE, EL, EN, ES, FR, HR, HU, IT, NL, RO, RU, SL, SR, SV) for BG, HR, CZ, DK, FR, DE, GR, HU, INT, IT, NL, RO, RU, RS, SI, ES, SE, US, AU, GB, CH, AT]
ConformX Instructions for use Seat Cushion
Category: Instructions for use
File name: 408901EN_02.pdf
Type: PDF
Size: 0.28 Mb
* Please check with your local sales representative if the product is available for sale in your country.