MaxxAir ETS

The MaxxAir ETS Mattress Replacement System (MRS) provides skin management therapies and enables safe patient handling for patients weighing up to 454 kg (1,000 lbs).

Designed for use with the BariMaxx™ II Therapy System and the BariMaxx™ II with Power Drive System.
With Low Air Loss (LAL) therapy, Continuous Lateral Rotational Therapy (CLRT), GORE® medical fabric and a turn assist feature, the MaxxAir ETSMRS is designed for use with the BariMaxx II Therapy System. The MaxxAir ETSMRS helps maintain skin integrity and improves safe patient handling, thereby reducing the risks of musculoskeletal injuries associated with bariatric care.
Indications
*Prevention and treatment of pressure injuries.
*Patients who are difficult to turn.
*Patients using a static mattress that would benefit from a pressure redistribution surface.
*Patients whose body weight and size pose a significant risk or care management issue to the patient or staff during routine nursing care procedures.
*Patients weighing up to 454 kg (1,000 lbs) (including accessories).
Contraindications
*Unstable cervical, thoracic and/or lumbar fractures.
*Cervical or skeletal traction.
*Patients with a total weight in excess of 454 kg (1,000 lbs) (including accessories).
*Please refer to product labelling and instructions for use for risks, precautions, warnings and detailed operating instructions prior to use.

* Please check with your local sales representative if the product is available for sale in your country.

Continuous Lateral Rotation Therapy (CLRT) offloads pressure by constantly changing the pressure points.
Low Air Loss (LAL) therapy provides airflow to help maintain skin temperatures and control and manage moisture.
GORE® medical fabric offers excellent moisture vapour permeability to create the optimum skin microclimate while serving as an effective barrier against fluid and bacteria.
Full body turn assist, up to 30°, helps facilitate resident/patient care by automatically repositioning and turning residents/patients.
Mattress expandability from 91 cm to 107 cm to 122 cm (36” to 42” to 48”) allows customisation of width for resident/patient comfort and safety while maintaining dignity and enabling easy transfers.
Rapid, convenient CPR deflation.
Easy-to-use controls at the foot of the bed for simplified nursing care.
454 kg (1,000 lbs) weight capacity accommodates high resident/patient weight in both static and turning positions.

* Please check with your local sales representative if the product is available for sale in your country.

The MaxxAir ETS Mattress Replacement System (MRS) provides skin management therapies and enables safe patient handling for patients weighing up to 454 kg (1,000 lbs). Designed for use with the BariMaxx™II Therapy System and the BariMaxx™ II with Power Drive System.

Dimensions
Mattress A (L x W x H) mm 2030 x 910 x 250 mm
Mattress A (L x W x H) in 80 x 36 x 25 in
Mattress A Weight kg 22 kg
Mattress A Weight lb 48 lb
Mattress B (L x W x H) mm 2030 x 1070 x 250 mm
Mattress B (L x W x H) in 80 x 42 x 10 in
Mattress B Weight kg 22 kg
Mattress B Weight lb 48 lb
Mattress C (L x W x H) mm 2030 x 1220 x 250 mm
Mattress C (L x W x H) in 80 x 48 x 10 in
Mattress C Weight kg 22 kg
Mattress C Weight lb 48 lb
Cell Material Polyurethane
Pump
Size (L x W x H) mm 17 x 42 x 27 mm
Size (L x W x H) in 6.7 x 16.5 x 10.5 in
Weight kg 5,7 kg
Weight lb 12,5 lb
Mode of Operation Continuous
Electrical Rating 60 Hz
Operating Cycle Time 3-30 minutes
Shock Protection Class II, Type BF
Ingress Protection IPX1
Power In 115 Volt, 5 Amp
Standards UL60601-1

* Please check with your local sales representative if the product is available for sale in your country.

Explore this product

Filter
Filter
MaxxAir ETS Instructions for use Mattress Replacement System User's Guide

Type: Instructions for use (IFU)

Language
DOWNLOAD
MaxxAir ETS Quick reference guide - Funcstions (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
MaxxAir ETS Quick reference guide - Use (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
PIP ETIK Brochure

Type: Sales | Leave behind / Brochure

Language
DOWNLOAD
PIP International Guidelines

Type: Clinical | Clinical summary and/or focus document

Language
DOWNLOAD
TSS WoundCare LTC Selection Tool

Type: Sales | Specifications sheet / Flyer

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

PIP ETIK Brochure

Type: Sales | Leave behind / Brochure

Language
DOWNLOAD
PIP International Guidelines

Type: Clinical | Clinical summary and/or focus document

Language
DOWNLOAD
TSS WoundCare LTC Selection Tool

Type: Sales | Specifications sheet / Flyer

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

MaxxAir ETS Instructions for use Mattress Replacement System User's Guide

Type: Instructions for use (IFU)

Language
DOWNLOAD
MaxxAir ETS Quick reference guide - Funcstions (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
MaxxAir ETS Quick reference guide - Use (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

Arjo technician helps customer

We are here for you!

Can’t find what you are looking for? Let us help.