You are visiting a website that is not intended for your region

The page or information you have requested is intended for an audience outside the United States. By continuing to browse you confirm that you are a non-US resident requesting access to this page or information. Switch to the US site. 

This website uses cookies

By continuing to use this website you consent to using cookies. For more information about cookies and how we use them, please see our Privacy Policy.

Nimbus Professional

The ultimate pressure redistribution mattress in the Nimbus™ range

The Nimbus® Professional system is the ultimate pressure redistribution mattress in the Nimbus range, offering advanced dynamic therapy and total resident/patient management for all care environments.

From the Intensive Care Unit (ICU) to extended care, across both medical and surgical environments, the Nimbus Professional system delivers a proven solution with unique customisation options of the therapy surface in order to meet a wide range of resident/patient management needs.

Additional features

The Nimbus Professional system provides the same dual therapy and features as the Nimbus 4, with the following additional features:

Head section deflate

The top 3 semi-dynamic cells can be deflated to remove pressure from below the head, or for providing access to the head and neck for specialist nursing procedures (i.e. intubation, cannulation or feed support lines).

Torso deflate

The sacral section of the mattress can be deflated to assist with nursing procedures such as bed to chair transfers, physiotherapy, low height resident/patient egress and specialised processes like C/D arm imaging and X-rays.

Zoned wound valve technology

This technology allows caregivers to selectively isolate any one of the 19 individual cells under a resident's/patient’s body, providing complete and permanent pressure relief, making this mattress one of the most adaptable support surfaces in the management of highly vulnerable areas, such as grafts, burns, wounds, heels and ischaemic legs.

(Zoned wound valve technology also facilitates the use of additional technologies, such as topical negative pressure therapy without compromising posture and comfort).

Key features

Automatt™ sensor pad
An Automatt sensor pad, below the entire length of the mattress, works with the automatic pump, constantly readjusting cell pressure to keep the interface pressure below 10 mmHg for up to 40% of the operating cycle.

Complete heelguard
Five heel cells incorporate vent valve technology, allowing the caregiver to fully remove interface pressure from this high risk area, and providing zero pressure for the most vulnerable residents/patients, such as those with limb ischaemia or existing wounds.

Transport facility
The mattress can be transformed from a powered support surface into a sealed static air mattress for up to 12 hours, providing a uniform stable surface for resident/patient transportation, nursing procedures, moving & handling and providing basic support in the event of a power failure.

CPR/RADR
Cardio Pulmonary Resuscitation (CPR) and Rapid Air Deflate Release (RADR) is a quick release, single-handed function located on the mattress control unit that enables rapid air deflation for emergencies, short-term physiotherapy, resident/patient transfers and handling or storage.

From the Intensive Care Unit (ICU) to extended care, across both medical and surgical environments, the Nimbus Professional system delivers a proven solution with unique customization options of the therapy surface in order to meet a wide range of patient management needs.

Nimbus Professional - Technical Information

Mattress (specifications apply to both
the Nimbus 4 and Nimbus Professional systems)

 StandardNarrow
Length2060 mm (81")2060 mm (81")
Width890 mm (35")800 mm (31 1/2")
Maximum height215 mm (8 1/2") – at edges215 mm (8 1/2") – at edges
Maximum profile height380 mm (15") – at edges380 mm (15") – at edges
Cell height203 mm (8") – inflated203 mm (8") – inflated
Weight (including packaging)15.5 kg (XX lbs)14.3 kg (XX lbs)
Cover materialPU coated knitted fabricPU coated knitted fabric
Cell material0.3 mm (XX") PU flexible sheeting0.3 mm (XX") PU flexible sheeting
Max patient weight250 kg (550 lbs)250 kg (550 lbs)

Pump

Length508 mm (20")
Height220 mm (8 3/4")
Depth100 mm (4")
Weight5.7 kg (25")
Case materialABS/polycarbonate blend
Supply voltage UK220-240 VAC, 50Hz
Electrical rating35 VA
Fuse ratingF500mA
FiltersAll service replaceable
Operating cycle10 minutes

Tube set

Length1000 mm (39 1/2")
Tube material5-way moulded PVC
Tube connectorsMoulded nylon

Electrical safety standards

IEC601-1 IEC 60601-1 (BS EN 60601-1) IEC 60601-1-2 (BS EN 60601-1-2) VDE 0750 Teil 1
Degree of protection against electric shockClass I, type BF
Degree of protection of ingress of liquidsOrdinary
Mode of operationContinuous

Key features

  • An Automatt sensor pad, below the entire length of the mattress, works with the automatic pump, constantly readjusting cell pressure to keep the interface pressure below 10 mmHg for up to 40% of the operating cycle.
  • Five heel cells incorporate vent valve technology, allowing the caregiver to fully remove interface pressure from this high risk area, and providing zero pressure for the most vulnerable patients, such as those with limb ischemia or existing wounds.
  • The mattress can be transformed from a powered support surface into a sealed static air mattress for up to 12 hours, providing a uniform stable surface for patient transportation, nursing procedures, moving & handling and providing basic support in the event of a power failure.
  • Cardio Pulmonary Resuscitation (CPR) and Rapid Air Deflate Release (RADR) is a quick release, single-handed function located on the mattress control unit that enables rapid air deflation for emergencies, short-term physiotherapy, patient transfers and handling or storage.

Nimbus 4 Nimbus Professional Instructions for Use

Category: Instructions For Use

File name: 649900EN_03.pdf

Type: PDF

Size: 0.66 Mb

GB-INT DE FR IT NL US


Nimbus 4 Nimbus Professional Instructions For Use

Category: Instructions For Use

File name: 649933US-P_01.pdf

Type: PDF

Size: 1.15 Mb

GB-INT


Nimbus 4 Instructions For Use

Nimbus 4 Instructions For Use

Category: Instructions For Use

File name: 649933ML_03-Library.pdf

Type: PDF

Size: 12.56 Mb

SA CH CZ DE DK ES FR IT NL PL PT SE TH NO IT TH SE PT DE NL PL FR ES DK CZ GB-INT US ES GB-INT HR


Nimbus 4

Category: Flyer (2 pages)

File name: 01.TS.33.1.SE.1.AHG.pdf

Type: PDF

Size: 0.3 Mb

SE GB-INT


Pressure Ulcer Prevention and Treatment Solutions - TS.CF.50.1.GB-INT.2.AHG-singlepages.pdf

EPUAP- NPUAP - PPPIA CLINICAL PRACTICE GUIDELINE 2014: Considerations on Support Surfaces, Safe Patient Handling and Pressure Ulcer Prevention for Clinicians Pressure Ulcer Prevention and Treatment Solutions - TS.CF.50.1.GB-INT.2.AHG-singlepages.pdf

Category: Brochure

File name: TS.CF.50.1.GB-INT.2.AHG.pdf

Type: PDF

Size: 3.04 Mb

GB GB-INT IT FR BE NL BE


01.ZZ.117.2.GB-INT.1.AHG - ICU Mobility Solutions

01.ZZ.117.2.GB-INT.1.AHG - ICU Mobility Solutions

Category: Brochure

File name: 01.ZZ.117.2.GB-INT.1.AHG.pdf

Type: PDF

Size: 0.58 Mb

GB-INT FR IT GB NL US ES PT DE


Nimbus Range - Advanced Mattress Replacement System

01.TS.20.3.GB-INT.1.AHG

Category: Brochure

File name: 01.TS.20.3.GB-INT.1.AHG.pdf

Type: PDF

Size: 0.54 Mb

BE GB-INT DE CZ IT DK BE BE NL GB PL US


Nimbus 3 Instructions For Use

Nimbus 3 Instructions For Use

Category: Instructions For Use

File name: 151996_08.pdf

Type: PDF

Size: 6.91 Mb

IT GR SE DE NL FR ES DK GB-INT US DK GR ES SE CH GB-INT DE AU NL IT FR CH


* Please check with your local sales representative if the product is available for sale in your country.