Multi-mode Mattress Replacement System (MRS) and overlay system for 24 hour pressure ulcer management

The Auto Logic™ 200 and 175 Mattress Replacement Systems and the  Auto Logic™ 110 Mattress Overlay System provide automatic, self-setting therapy options with the benefit of a battery-powered active transportation function.

The Auto Logic range is recommended for round-the-clock pressure ulcer prevention and management of all stages in combination with a resident/patient specific monitoring, repositioning and wound care programme.

The Auto Logic pump uses Self Set Technology (SST) to regularly assess the resident's/patient's body mass distribution and readjusts cell air pressures to meet their specific needs ensuring optimum pressure area management.

  • Active therapy (alternating) and reactive therapy (constant lower pressure) modes.
  • Cell in cell system centralises resident/patient on the mattress and increases stability at the edge to assist during transfers..
  • Curved cell design prevents residents/patients from creeping down the bed.
  • Cable management - no trailing power cables.
  • Comfort control for a softer or firmer surface improving comfort without compromising performance.
  • Battery - offers a minimum of six hours of therapy in the event of a power supply failure or active transportation to another department.

Multi-mode Mattress Replacement and Mattress Overlay Systems for 24 hour pressure redistribution.

The Auto Logic™ 200 and 175 Mattress Replacement Systems and the Auto Logic™ 110 Mattress Overlay System provide automatic, self-setting therapy options with the benefit of a battery-powered active transportation function.

The Auto Logic range is recommended for round-the-clock pressure ulcer prevention and management of all stages in combination with a resident/patient specific monitoring, repositioning and wound care programme.

The Auto Logic pump uses Self Set Technology (SST) to regularly assess the resident's/patient's body mass distribution and readjusts cell air pressures to meet their specific needs ensuring optimum pressure area management.

Technical information

Measurements and weights

 Auto logic 110 OverlayAuto logic 200 Matress ReplacementAura logic Seat cushion
Length2030 mm (80”)2030 mm (80”)470 mm (18 1/2”)
Width860 mm (34”)860 mm (34”)455 mm (18”)
Height115 mm (4 1/2”)205 mm (8”)50 mm (2”)
Air filled sub-mattress 2030 mm x 860 mm x 90 mm
(80” x 34” x 3 1/2”)
 
Cell materialpolyurethane (PU)polyurethane (PU)polyurethane (PU)
Base cover materialPU coated nylonPU coated nylon 
Max resident/patient weight200 kg (441 lbs)200 kg (441 lbs)200 kg (441 lbs)

Auto logic 175 Mattress Replacement

Length2030 mm (80”)
Width860 mm (34”)
Height175 mm (7”)
Foam underlay Size2032 mm x 838 mm x 63.5 mm (80” x 33” x 2 1/2”)
Cell materialpolyurethane (PU)
Max resident/patient weight200 kg (441 lbs)

Pump

Length375 mm (14 3/4”)
Height280 mm (11”)
Depth125 mm (5”)
Weight2.75 kg (6 lbs)
Case materialABS plastic
Mode of operationcontinuous
Power supply voltage/frequency100 - 240 VAC/50 - 60 Hz
Electrical rating85 VA MAX
Operating cycle time10 minutes
Degree of protection against electric shockclass II double insulated with functional earth type BF (mains connected)
Degree of protection of ingress of liquidsIPX0

The Auto Logic multi-mode pump offers leading pressure management, providing an active therapy (alternating) mode and a reactive therapy (constant lower pressure) mode.

Key features

  • Active therapy (alternating) and reactive therapy (constant lower pressure) modes.
  • Cell in cell system centralises resident/patient on the mattress and increases stability at the edge to assist during transfers..
  • Curved cell design prevents residents/patients from creeping down the bed.
  • Cable management - no trailing power cables.
  • Micro air loss - helps reduce humidity at the resident/patient mattress interface.
  • Comfort control for a softer or firmer surface improving comfort without compromising performance.
  • Battery - offers a minimum of six hours of therapy in the event of a power supply failure or active transportation to anoher department.

Pressure Ulcer Prevention and Treatment Solutions - TS.CF.50.1.GB-INT.2.AHG-singlepages.pdf

EPUAP- NPUAP - PPPIA CLINICAL PRACTICE GUIDELINE 2014: Considerations on Support Surfaces, Safe Patient Handling and Pressure Ulcer Prevention for Clinicians Pressure Ulcer Prevention and Treatment Solutions - TS.CF.50.1.GB-INT.2.AHG-singlepages.pdf

Category: Brochure

File name: TS.CF.50.1.GB-INT.2.AHG.pdf

Type: PDF

Size: 3.04 Mb

GB GB-INT IT FR BE NL BE


Logic Range Mattress Replacement & Overlay Systems

01.TS.07.4.GB-INT.1 AHG

Category: Brochure

File name: 01.TS.07.4.GB-INT.1.AHG.pdf

Type: PDF

Size: 0.46 Mb

DK IT ES DE NL GB-INT BE BE US PL GB NO


AUTOLOGIC 200 Mattress REPLACEMENT

01.TS.47.2.GB-INT.1.AHG - AUTOLOGIC 200 Mattress Replacement

Category: Flyer (2 pages)

File name: 01.TS.47.2.GB-INT.1.AHG.pdf

Type: PDF

Size: 0.29 Mb

GB-INT DK IT DE NL


AUTOLOGIC 110 Mattress OVERLAY

01.TS.49.3.GB-INT.1.AHG - AUTOLOGIC 110 Mattress OVER LAY

Category: Flyer (2 pages)

File name: 01.TS.49.3.GB-INT.1.AHG.pdf

Type: PDF

Size: 0.2 Mb

GB-INT IT DK NL


Auto Logic Instructions for Use

Instructions for Use for the Auto Logic

Category: Instructions For Use

File name: 630933EN_05.pdf

Type: PDF

Size: 1.18 Mb

TR GR CZ DE DK GB-INT ES BO BR CL CO DO EC MX PA PY PE TT UY VE FR IT NL NO PL OT RU SE TH US RO


* Please check with your local sales representative if the product is available for sale in your country.